Calculate volumetric flow rate from measured differential pressure across an orifice plate
Pipe & Orifice Geometry
Fluid Properties
Differential Pressure
Key Formulas
Orifice Flow Rate (ISO 5167)
Q = Cd · (Ï€/4) · d² · √(2ΔP / Ï(1−βâ´))Beta Ratio
β = d / DDischarge Coefficient (Reader-Harris/Gallagher)
Cd = 0.5961 + 0.0261β² − 0.216β⸠+ ...Kv (metric)
Kv = Q / √(ΔP_bar / SG)Cv (imperial)
Cv = Kv / 0.865Permanent Pressure Loss
ΔP_loss = ΔP × (1 − 2.1β² + 2.9βâ¸)Typical Orifice Plate Data
| β Ratio | Cd (approx) | ΔP Recovery % | Typical Tag Size |
|---|---|---|---|
| 0.20 | 0.597 | 96% | Small flow, high ΔP |
| 0.30 | 0.598 | 91% | Low range |
| 0.40 | 0.603 | 84% | Common |
| 0.50 | 0.608 | 74% | Common (optimum) |
| 0.60 | 0.613 | 62% | Common |
| 0.70 | 0.617 | 48% | High flow range |
| 0.75 | 0.620 | 40% | ISO limit |